Optimum structural design with fire&water mixing tube make smaller boiler volume and can save 1/3 building cost of boiler house
Spirally corrugated tubes achieve 1-2times higher heat transfer efficiency
Aerofoil-shaped flue greatly reduce the thermal burden of the boiler
Convex tube sheet enhance its toughness and avoid seam crack
New boiler arch with dust separation space, dust consistence below national standard
Highest boiler efficiency & steam wetness below 1%
Applied advanced water circulation technology, low requirements to water
Model DZH1-1.0-AII Specification:
| Model | DZH1-1.0-AII |
| Rating steam capacity ( t/h) | 1 |
| Rating pressure (MPa) | 1.0 |
| feed water temperature (°C) | 20 |
| Rating steam temperature (°C) | 184 |
| Grate active area ( m2) | 1.85 |
| Applied coal | soft coal II |
| Exhaust gas temperature (°C) | 157.3 |
| Boiler efficiency (%) | 80.33 |
| Coal consumption (Kg/h) | 118 |
| Max transportation weight (t) | 14.2 |
| Transportation dimension (mm) | 5488*2000*2832 |
| Boiler installation dimension ( mm) | 5900*2600*3252 |
| Factory packing method | package boiler |
Steam Boiler